hero_megaboard
Non-Combustible Water-Resistant Mould and Mildew Resistant Termite Resistant Impact Resistant

MEGABOARD Testing & Technical

MEGABOARD Testing & Technical

ReGen Building Solutions also takes its responsibilities for supplying products extremely seriously. To ensure we supply products that are Fit for Purpose, because we have and continue to invest in testing to ensure the products we supply direct or third party products we supply as part of our systems meet our quality requirements.

ReGen Building Solutions that has worked with manufacturers, suppliers, NATA testing labs, universities and associations to develop a range of tests also for the products we supply to our end-user customer. All recommended 3rd party products have also been tested by the suppliers to ensure the products perform and interact appropriately with MEGABOARD to ensure long term durability.

Our 3rd party suppliers include:

3M – Glues, sealants and tapes

Valspar – Granosite render, internal/external paints and sealants

Astec – Renders and paint

SteedForm – Lamination

Our Testing partners include:

Ian Bennie & Associates Pty. Ltd. NATA approved – Waterproofing and wind loads

Laminex – Bend strength NATA approved

Ignis Fire Solutions – BAL Rating/non-combustibility

University of South Australia – Bend tests

AWTA – Thermal Resistance NATA approved

SLR – Acoustics

Bureau Veritas – Asbestos NATA approved

Intertek – EU 12467:2012 +A1 2016 Fibre Cement Flat Sheets – Product Specifications and test results

Independent Certification

Acronem Consulting

Ignis Fire Solutions

MEGABOARD Dimensional and Weight Properties

MEGABOARD also comes in a range of different sizes, thicknesses and edging finishes.

Please contact Regen Building  0412 341 587 to confirm availability of stock.

Thickness
mm
Length
mm
Width
mm
M2 Weight
kg
EDGING
Recessed Square
6 2400 1200 2.88 17
6 2700 1200 3.24 19
6 3000 1200 3.6 21
8 2400 1200 2.88 28
8 2700 1200 3.24 31
8 3000 1200 3.6 35
10 2400 1200 2.88 34
10 2700 1200 3.24 38
10 3000 1200 3.6 42
12 2400 1200 2.88 36
12 2700 1200 3.24 41
12 3000 1200 3.6 45

 

MEGABOARD Testing

MEGABOARD goes through independent testing incorporating separate tests before boards are accepted for cladding internal or external applications. The tests for the boards are outlined in the below table and must pass prior to being accepted by ReGen Building Solutions.

Tests are based on the following testing regimes and must pass before being accepted

Cladding span tables

MEGABOARD span tables 6mm – currently being reviewed. Please contact ReGen Building for further information

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 450 200 450 300
N2 450 200 450 300
N3 200 450 300
N4 200 300
N5 200 300
N6 200 300

 

MEGABOARD span tables 8mm – currently being reviewed. Please contact ReGen Building for further information

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support also spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 450 200 600 300
N4 450 200 450 300
N5 450 200 450 300
N6 200 450 300

MEGABOARD span tables 10mm – currently being reviewed. Please contact ReGen Building for further information

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 450 200 600 300
N4 450 200 450 300
N5 450 200 450 300
N6 200 450 300

MEGABOARD span tables 12mm – currently being reviewed. Please contact ReGen Building for further information.

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 600 200 600 300
N4 600 200 600 300
N5 600 200 600 300
N6 600 200 600 250

Terms and Conditions

Asbestos Report

External Cladding

Soffits and Eaves

Sacrificial formwork

Coating specifications External Wattyl/Solver/Granosite

Coating specifications Internal Wattyl/Solver/Granosite

Coating Specification Exterior Rockcote

 

 

Sign up to our email newsletter to receive the latest news and updates